A shield comparison becomes difficult to interpret when the probe moves between samples. Before deciding that one lid is better, establish whether the same assembly gives a repeatable result after removal and replacement in the fixture. This is a measurement-design task, not a supplier ranking exercise.
Choose a location that can be recovered
Start with a photograph of the board and mark the suspect seam segment. Reference the probe position to stable board features, rather than to the edge of a removable lid. Record which face of the loop points toward the assembly, the approach direction, and the intended clearance. A photograph without a height reference is insufficient for a later operator to recover the same position.
Tektronix identifies consistent probe placement and orientation as essential to repeated relative near-field measurements. The fixture and sequence below are proposed engineering controls for applying that principle; they are not a prescribed certification method.
Prove the fixture before comparing lids
Use the original lid and acquire several independent captures. Between captures, withdraw the probe and return it to the recorded position. Then repeat after removing and refitting that same lid. These two exercises separate probe-position variation from changes caused by the lid engagement itself. Keep the raw traces, including unsuccessful placements, so the observed spread is not hidden by selecting the best screenshot.
Support the board without pressing its corners or pulling its connectors. A fixture that straightens a warped board can change the assembly being evaluated. Route the probe cable away from the board in the same way on every run, and photograph that route. Check that the holder does not obstruct cooling or touch exposed conductors.
Run an A/B/A sequence
- Measure the original assembly, A, with the specified firmware and workload.
- Fit candidate B without moving the board or changing cables, then repeat the same capture.
- Refit A and acquire a final reference measurement.
- Compare both A records before deciding whether the B difference is meaningful.
If the two A results disagree substantially, investigate the sequence instead of averaging away the disagreement. The board might have warmed up, the lid might not have reseated, or the active workload might have changed. The acceptable reference spread must come from the project measurement plan; a universal decibel threshold would conceal these differences.
Keep a compact comparison record
| Record | What to preserve | Why it matters |
|---|---|---|
| Specimen identity | Board revision, lid revision and assembly history | Prevents a geometry change from being attributed only to material |
| Probe geometry | Position, standoff, orientation and holder photograph | Makes the physical measurement recoverable |
| Operating state | Firmware, supply, workload and capture timing | Checks whether both lids were exposed to the same source activity |
| Reference return | Initial and final A traces with observation notes | Reveals drift that could invalidate the comparison |
Decide what the result actually supports
A repeatable reduction at one probe location supports a local comparison under the recorded conditions. It does not establish a general shielding-effectiveness value or show that every radiating path improved. Preserve promising candidates for assembled-product testing and verify other known problem frequencies before changing the drawing.
For a shield sample review, provide the contact geometry and the observed location alongside the drawing. Describe the fixture separately from the proposed production assembly.
FAQ
Can I hold the probe by hand?
Handheld scanning is useful for finding a region of interest. A repeatable comparison needs a recoverable position and an estimate of the variation introduced by repositioning.
Should I report only the largest peak?
Keep the relevant frequency range and marked frequencies. A lower maximum may hide a different peak becoming dominant or a signal moving away from the original marker.
Does A/B/A eliminate every confounding factor?
No. It exposes some drift but cannot correct an undocumented workload or damaged contact. Investigate failed reference returns before making a design decision.